Skip image slider
XPR Shield 420228
XPR Shield 420228
XPR Shield 420228
XPR Shield 420228

XPR 30A Shield 420228 for Plasma Cutting

XPR Shield 420228 is a compatible replacement plasma shield for specified 30A XPR mild steel cutting configurations. Designed for the O₂/O₂ process, this 30A shield works with the matching nozzle, swirl ring, electrode, and retaining components in compatible mechanized plasma cutting systems.

PRODUCTS CATEGORIES
PRODUCT DESCRIPTION

XPR Shield 420228 Replacement for 30A Plasma Cutting

The XPR Shield 420228 is a compatible replacement consumable designed for specified 30A mild steel cutting applications on XPR plasma systems. It is used with the O₂/O₂ gas process, in which oxygen is used for both plasma gas and shield gas in the listed configuration.

The shield is part of the plasma torch consumable assembly. It helps protect the torch area and supports the intended operating configuration around the nozzle and plasma arc. Selecting the correct shield is important because different amperages and cutting processes use different consumable combinations.

For the specified 30A O₂/O₂ configuration, shield 420228 is paired with nozzle 420225, swirl ring 420407, electrode 420222, and water tube 420368. The assembly also includes shield cap 420200 and nozzle retaining cap 420365. Confirm the complete consumable stack against the applicable equipment documentation before ordering.

For industrial users, XPR Shield 420228 provides a compatible replacement option for routine torch maintenance and spare-parts inventory management.

Key Features

  • Part Number: 420228 compatible replacement plasma shield.
  • Applicable Current: 30A in the specified configuration.
  • Cutting Application: Mild steel cutting.
  • Gas Process: O₂/O₂.
  • Compatible Consumables: Designed for use with the matching nozzle, swirl ring, electrode, and retaining components.

XPR Shield 420228

Product Specifications

Item Specification
Product Name XPR Shield
Part Number 420228
Product Type Plasma torch shield
Compatible System Series XPR170 / XPR300 / XPR460, subject to system configuration
Applicable Current 30A
Cutting Material Mild steel
Specified Process O₂/O₂
Shield Cap 420200
Nozzle Retaining Cap 420365
Nozzle 420225
Swirl Ring 420407
Electrode 420222
Water Tube 420368
Product Type Compatible replacement consumable

Compatibility note: These specifications refer to the listed 30A O₂/O₂ configuration. Verify the equipment model, gas process, and complete consumable assembly against the applicable system documentation before ordering.

Compatible Consumable Configuration

The following table shows the specified consumable stack for shield 420228.

Component Part Number
Shield Cap 420200
Shield 420228
Nozzle Retaining Cap 420365
Nozzle 420225
Swirl Ring 420407
Electrode 420222
Water Tube 420368

The components work as a specified assembly for the 30A O₂/O₂ process. Do not substitute shields intended for other amperages or gas processes without checking the relevant consumable chart.

XPR Shield 420228

Difference Between Shield 420228 and Shield Cap 420200

Shield 420228 and shield cap 420200 perform different roles in the torch assembly.

Comparison Shield 420228 Shield Cap 420200
Component Type Shield Shield retaining cap
Part Number 420228 420200
Role Part of the torch shielding assembly Retains the shield assembly
Application Specified 30A O₂/O₂ configuration Used in multiple compatible XPR configurations

These parts are not interchangeable. When ordering replacements, confirm whether the required component is the shield itself or the retaining cap.

Applications of XPR Shield 420228

The XPR Shield 420228 is intended for compatible mechanized plasma cutting operations involving mild steel in the specified 30A O₂/O₂ configuration. It can be used in industrial fabrication workshops, metal-processing facilities, and manufacturing environments operating compatible XPR plasma systems.

For maintenance teams, keeping the correct shield available helps support planned torch servicing and consumable replacement. Matching the shield with the specified nozzle, swirl ring, and electrode also helps prevent errors when replenishing consumable inventories.

Inspect the shield and associated torch components according to the equipment manufacturer’s maintenance instructions. Replace worn or damaged parts when required, and follow all relevant safety procedures when servicing plasma cutting equipment.

Compatible Replacement Consumables from ALLWIN

ALLWIN supplies compatible replacement plasma consumables for industrial cutting applications. When sourcing XPR Shield 420228, verify the 30A O₂/O₂ process and matching part numbers to ensure the selected shield is suitable for the intended torch assembly.

Browse the XPR170 and XPR300 plasma consumables collection for related replacement parts, or visit the ALLWIN website.

For information about industrial cutting equipment, explore FWincnc CNC plasma cutting machines.

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)